SCSI sense failure [2]
Array Disk X:X SCSI sense failure
機種:PowerEdge 1750
PERC:4/DI Controller
IT Assistant Alart Mail
----------------------------------------------------------------------------------------------------
System: XXXXXXX, Service Tag: XXXXXXX, Asset Tag:
Date: 200X/XX/XX, Time: XX:XX:XX, Severity: 警告
Message: PERC 4/DI Controller X, Array Disk X:X SCSI sense failure.
----------------------------------------------------------------------------------------------------
DELL OpenManage Array Manager Event Details
----------------------------------------------------------------------------------------------------
PERC 4/DI Controller 1, Array Disk X:X Sense key = 4, Sense code = 40, Sense Qualifier= 8C.
If this disk is part of a redundant virtual disk, select the 'Offline' option and then replace the disk.
Then configure a hot spare and it will start the rebuild automatically.
If this disk is part of a non-redundant disk, you should back-up your date immediately.
If the disk fails, you will not be able to recover the data.
----------------------------------------------------------------------------------------------------
DELLに確認したところ
[Array Disk X:X Sense key = 4, Sense code = 40, Sense Qualifier= 8C.]
上記のメッセージが出た場合はHDD交換を勧められます
HDD内部に不良ブロックや不良セクタが発生した際に検知するメッセージとなり、
現在HDDがONLINEの状態でも、今後FAILする可能性が高いとのことでした
※Sense Key = 4 は分類として「ハードウェアエラー」、「重大なハードウェア障害が発生」という区分になるため
ハードウェアの交換が必要となる数値だそうです
※あくまでも作業は自己責任でお願いします
※不明点はDELLに確認しましょう